How Can I Account For Continuous Tie Rods in RISA-3D Wood Walls?

How Can I Account For Continuous Tie Rods in RISA-3D Wood Walls?
 

Continuous tiedown systems are used to help resist overturning forces generated by lateral loads, and can be estimated in RISA-3D using the hold-down database and the strap forces.

The Holddown Excel database is located in the RISA>Wood Schedules>HoldDowns folder and contains the parameters for the deflection calculations from the NDS 2015 Special Design Provisions for Wind and Seismic, Equation 4.3-1:

Continous Tie Rod2

In order to account for the uplift effects of the tiedown (rod elongation, bearing deformation, fastener slip, etc.) you need to change the change Δa. A good estimate of this value is listed below:

Continous Tie Rod3

P= Allowable Tension

L= Length of the rod

A= Area of the rod

E= Stiffness of the rod

It is important to note that this assumes a tied-off system which distributes loads at each level rather than a skipped story system.

The manufacturers of the tiedowns require the tension forces at each floor level, and you can find the Strap Forces from Wall Detail Report. This can also be used to select the appropriate tiedown for the wall from the manufacturer’s charts listed under Allowable Tension Capacity based on the wood material.

Cont tie rod 3

 

You may also be interested in

 
How to Apply Hydrostatic Loads to Circular Tanks in RISA-3D
JUNE 07, 2012

How to Apply Hydrostatic Loads to Circular Tanks in RISA-3D

RISA-3D v10 now has the ability to quickly and easily apply hydrostatic loads to circular tanks using the Cylinder Generator. This generator can...

Read More
Refining Area Load Distribution in RISA-3D
APRIL 20, 2011

Refining Area Load Distribution in RISA-3D

After solving a model with Member Area Loads, RISA-3D will automatically create Transient Basic Load Cases that allow the user to verify load...

Read More
Using Sum of Reactions in RISA-3D
APRIL 18, 2011

Using Sum of Reactions in RISA-3D

RISA-3D will now check your model for errors by summing the reactions in your model and comparing them to the applied loads. This occurs for the...

Read More