How to Correctly Define Unbraced Lengths
There are four different values for Unbraced lengths in RISA-3D, RISA-2D and RISAFloor. Two are for axial calculations and two are for bending...
Steel
Wood
Concrete
Education
RISA-3D
RISAFloor
RISAConnection
ADAPT-Builder
RISACalc
RISAFoundation
ADAPT-PT/RC
RISASection
RISA-2D
ADAPT-Felt
Link Utilities
![]()
Try the Complete RISA Suite for
10 Days FREE
Training
Webinars
Reach an Engineer
Tips & Tricks
Design Codes
Case Studies
New Features
Cloud Licensing

RISA Education
Video Library
Downloads
Licensing Support
Customer Portal
Product Documentation
System Requirements
Specifications
Online Help
Get Support
Contact
Careers
Employee Spotlight
Nemetschek
License Agreement
Privacy Policy
Open BIM
Partners

About Us
The bending and axial code checks for single angles differ somewhat from other shape types, because single angles behave quite differently in bending and compression depending on how they are braced along their length.
Single angles can act about their geometric axes if they are fully braced against twisting along their length. Otherwise they will bend and buckle about their principal axes.
RISA-3D will automatically assume that full bracing is not present, and that bending and buckling will occur about the principal axes. This is a conservative assumption. In the Detail Report of a single angle bending about its principal axes, the moments are reported as (Mz’) and (My’), which are the bending moments about the principal axes.
If you want the code check for your single angle to be based on bending and buckling about the geometric axes, then you must specify to the program that the angle is fully braced against twisting along its entire length. You can do this by entering an unbraced length of zero for both the Lcomp top and Lcomp bot values.
The program will use the values of Lbyy and Lbzz to determine the compression capacity of the angle.
There are four different values for Unbraced lengths in RISA-3D, RISA-2D and RISAFloor. Two are for axial calculations and two are for bending...
In the RISA-3D when you model a WT brace it exists at the member centroid, which means that no bending ends up in the brace due to the fact that...
When solving a RISA-3D model you may find you have a Shear UC (unity check) much higher than expected from bending shear alone. If you open the...