Why Is My Beam Failing in Shear?

Why Is My Beam Failing in Shear?

When solving a RISA-3D model you may find you have a Shear UC (unity check) much higher than expected from bending shear alone. If you open the detail report and compare the shear demand to the shear capacity you may see that the demand/capacity is less than the Max Shear Check reported.

Shear1

What is likely occurring is that the member has torsion in it. In RISA-3D both the bending and shear demands are affected by torsion, though it is shear that usually causes the most problems. If you look at the detail report and in the Member Torsion spreadsheet results you can see this torsion.

Shear2

Warping Member (Wide Flange, Channel, etc):

Shear3

Non-Warping Member (Tube, Pipe, etc):

Shear 4

Generally speaking wide flanges and channels work very poorly in torsion, while tube sections are much more efficient. Eliminating torsion or using a more efficient section are common ways to eliminate this problem. Note that this torsion problem can happen for all material types.

You may also be interested in

 
Understanding Out-of-Plane Shear Capacity of Concrete Wall Panels
APRIL 07, 2020

Understanding Out-of-Plane Shear Capacity of Concrete Wall Panels

When designing concrete shear walls for lateral loading, RISA-3D includes design checks for both in-plane and out-of-plane shear. In the condition...

Read More
How to Check Frame Story Shears in RISA-3D
NOVEMBER 29, 2010

How to Check Frame Story Shears in RISA-3D

When using rigid diaphragm analysis in RISA-3D it can be useful to evaluate the story shear in each frame. This is a perfect application for the...

Read More
Wood Wall Panels - Straps vs Hold-Downs
OCTOBER 11, 2018

Wood Wall Panels - Straps vs Hold-Downs

With the recent release of RISA-3D v17 the program now offers the user the option to use Chord Straps between floors of a wood shear wall building...

Read More